RF Coils

Hall C
Monday: 14:00 – 16:00

1388.   The Coaxial Reentrant Cavity (ReCav) Coil for High Frequency Large Volume MRI/S, B.L. Beck, H.R. Brooker and S.J. Blackband, University of Florida, Gainesville, FL, USA; The National High Magnetic Field Laboratory, Tallahassee, FL, USA and the University of South Florida, Tampa, FL, USA.
1389.   The Feasability of Transversal Volume Imaging in SMASH, M. Nittka, M. Griswold, R. Heidemann and A. Haase, Universität Würzburg, Würzburg, Germany.
1390.   The Double Tuned ¹H ²³Na Crosscage Resonator for High Field NMR Microscopy, T. Lanz, A. Weisser and A. Haase, Universität Würzburg and Rapid Biomedical, Würzburg, Germany.
1391.   B1 Field Plots for a 3 Tesla Birdcage Coil: Concordance of Experimental and Theoretical Results, M. Alecci, C.M. Collins, M.B. Smith and P. Jezzard, John Radcliffe Hospital, University of Oxford, Oxford, UK and Penn State College of Medicine, Hershey, PA, USA.
1392.   B1 Field Profile Along the Birdcage Coil Axis and its RF Shield Dependence, S. Li, Q. Liu, C.M. Collins, P.D. Haig, P.J. Delp and M.B. Smith, GE Medical Systems, Waukesha, WI, USA and Penn State College of Medicine, Hershey PA, USA.
1393.   A New 3.0T Hybrid-Spiral-Birdcage (HSB) Coil for Improved Homogeneity Along Z-Axis, J.S. Pak, J. Kim, J-O. Lee, B-S. Park, S-P. Jung, K-J. Jung and J. Kim, KAIST and MEDISON Co. Ltd, Taejon, Korea.
1394.   A 4 Channel Head Coil for SENSE Imaging, D.J. Herlihy, D.J. Larkman, H. Fujita, M. Burl and J.V. Hajnal, Hammersmith Hospital, London, UK and Picker International Inc., Cleveland, OH, USA.
1395.   A Four Port Drive Flat-Element Transmission-Line Coil for Brain Imaging at 3T, P.J. Ledden, L.L. Wald and J.T. Vaughan, Nova Medical, Inc. Wakefield MA, USA; Massachusetts General Hospital, Charlestown, MA, USA and University of Minnesota, Minneapolis, MN, USA.
1396.   Use of a Transmission Line Resonator as a Volume Phased Array, P.J. Ledden and L.L. Wald, Nova Medical, Inc. Wakefield, MA, USA and Massachusetts General Hospital, Charlestown, MA, USA.
1397.   An Efficient Model for Evaluating the Effects of Leg Current Distributions on Birdcage Coils, D.K. Spence and S.M. Wright, Texas A&M University, College Station, TX, USA.
1398.   A 4-Channel Volume Coil for Vertical Field MRI, G.R. Duensing, U. Gotshal and D. Molyneaux, MRI Devices Corporation, Gainesville, FL, USA.
1399.   "Millipede" Imaging Coil Design for High Field Micro Imaging Applications, W.H. Wong and S. Sukumar, Varian NMR Systems, Palo Alto, CA, USA.
1400.   High Resolution in Vivo Magnetic Resonance Imaging of the Skin and Comparison to High Frequency Ultrasound, A. Liffers, M. Vogt, H. Ermert, C. Müller, A. Falk, L. Heuser and S. El Gammal, Ruhr-University, Bochum, Germany.
1401.   Theoretical and Experimental Optimisation of the Dead Time of RF Coils, M. Alecci, G. Placidi, D.J. Lurie and A. Sotgiu, Universita' dell'Aquila, L'Aquila, Italy and University of Aberdeen, Foresterhill, UK.
1402.   Rigid Signal-to-Noise Analysis of Coupled MRI Coils Connected to Noisy Preamplifiers and the Effect of Coil Decoupling on Combined SNR, A. Reykowski and J. Wang, Siemens Medical Engineering, Erlangen, Germany.
1403.   Asymmetric Coil Sensitivity in Two-Coil Phased Array Due to Magnetic Interactions, E. Ramsay, J. Bishop and D.B. Plewes, University of Toronto, Toronto, Ontario, Canada.
1404.   Intrinsic RF Coil Isolation in a Gradient B1-Field, S.B. King, S.M. Varosi and G.R. Duensing, MRI Devices Corporation, Gainesville, FL, USA.
1405.   RF Coil Sensitivity Estimation for Intensity Correction or Encoding, D.F. Kacher, E. Gao, H.M. O'Leary, W.E. Kyriakos, J.P. Kaufhold, Q.Y. Ma, W.M. Wells and F.A. Jolesz, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA; Hong Kong University, Hong Kong, China and Boston University, Boston, MA, USA.
1406.   Zero Shared Resistance Between Coil Elements of a Phased Array?  S.B. King and G.R. Duensing, MRI Devices Corporation, Gainesville, FL, USA.
1407.   Empirical Description of the SNR Pattern of Shaped Circular Surface Coils, T. Prock, D.J. Collins and M.O. Leach, Institute of Cancer Research and Royal Marsden Hospital, Sutton, Surrey, UK.
1408.   A Simple Two-Dimensional Model for Dielectric Resonance, J. Tropp and J. Dahlke, GE Medical Systems, Fremont CA and Waukesha, WI, USA.
1409.   Electromagnetic Analysis and Design of Magnetic Resonance Radio Frequency Coils Using the Finite-Difference Time-Domain Technique, J.R. Hadley and D.L. Parker, University of Utah, Salt Lake City, UT, USA.
1410.   FDTD Analysis of an MRI System Housed in a Screened Room, H. Fujita, I.R. Young, R.S. Orton, W.M.A. Qureshi, M. Burl, M.A. Morich and J.V. Hajnal, Picker International Inc., Cleveland OH, USA; Marconi Research Centre, Chelmsford, UK and Hammersmith Hospital, London, UK.
1411.   High Temperature Superconducting RF Coil for MR Microscopy at 600 MHz, D. Lee, S. Baek, H. Choi, K. Lee and J-T. Kim, Pai Chai University and Korea Research Institute of Standards and Science, Taejon, South Korea.
1412.   Simulation of the Sensitivity of HTS Coil and Coil Array for Head Imaging, E. Gao, D.F. Kacher, K.C. Chan, Q.Y. Ma, F.A. Jolesz and E.S. Yang, Hong Kong University, Hong Kong, China and Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA.
1413.   Design & Testing of Superconducting Surface Coil Using MoM, F. Jing, M.S. Chow, E.K. Chan, K.K. Wong, E. Gao, Q.Y. Ma and E.S. Yang, The University of Hong Kong, Hong Kong.
1414.   An Image-Based Stray RF Current Measurement Technique, C.C. Guclu, K.C-H. Wu and S. Murawski, GE Medical Systems, Milwaukee, WI, USA.
1415.   Probe For ¹H Decoupled ³¹P MRS of the Head and Neck Region, D. Klomp, D. Collins, H. van den Boogert, A. Schwarz, M. Rijpkema, T. Prock, M. Leach and A. Heerschap, University Hospital Nijmegen, Nijmegen, The Netherlands and Royal Marsden Hospital, Sutton, Surrey, UK.
1416.   Rapidly Switchable RF Coil for 19F/¹H NMR Studies, S-P. Lee, I-Y. Choi and S-G. Kim, University of Minnesota Medical School, Minneapolis, MN, USA.
1417.   A Flexible Dual Resonant ¹H/19F RF Coil for In-Vivo Magnetic Resonance Spectroscopy, D.J. Collins, T. Prock and M.O. Leach, Institute of Cancer Research and Royal Marsden Hospital, Sutton, Surrey, UK.
1418.   Electrode Probes for Interventional MRI, G.C. Scott, G.E. Gold, J.M. Pauly, P. Rivas and B.S. Hu, Stanford University, Stanford, CA, USA.
1419.   High Resolution MRI at 1.0 T: Using an Intravascular Receiver Coil, J.T. Heverhagen, V. Matschl, M. Kalinowski, H. Alfke, K.J. Klose and H-J. Wagner, Philipps University and University Hospital, Marburg, Germany.
1420.   Calculation of SNR for 2- and 4- Coil Breast Arrays, E. Ramsay, J. Bishop and D.P. Plewes, University of Toronto, Toronto, Ontario, Canada.
1421.   Comparison of Breast Coils, E. Ramsay, N. Konyer, M.J. Bronskill and D.B. Plewes, University of Toronto, Toronto, Ontario, Canada.
1422.   Development of Breast STS Coil with Optimized RF Field Uniformity, M-N. Kim, E-J. Kim, D-H. Kim, S-A. Shin and E-K. Jeong, Ewha Womans University and Yonsei University, Seoul, Korea.
1423.   fMRI on Primates with Custom Tailored RF Coils, H. Merkle, M. Augath, T. Trinath, N. Logothetis and K. Ugurbil, The University of Minnesota Medical School, Minneapolis, MN, USA and Max Planck Institute for Biological Cybernetics, Tuebingen, Germany.
1424.   Effects of Coil Design on the Sensitivity of Functional MRI to Task Related Activation, K. Arfanakis, D. Cordes, L. Latour, V.M. Haughton, M.A. Quigley and M.E. Meyerand, University of Wisconsin, Madison, WI, USA and IGC Medical Advances, Milwaukee, WI, USA.
1425.   RF Coil Optimization for 0.015 Tesla Very Low-Field Hyperpolarized Noble Gas MRI, Y.J. Yang, M.S. Albert, K.H. Min, A.X. Zhang, A.K. Venkatesh, G.R. Gomez, D. Balamore, R.S. Hashoian, C-L. Chin and C.H. Oh, Korea University, Seoul, Korea; Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA; Nassau Community College, Garden City, NY, USA and Midwest RF, Hartland, WI, USA.

Return to ISMRM program