ISMRM 21st Annual Meeting & Exhibition 20-26 April 2013 Salt Lake City, Utah, USA

SCIENTIFIC SESSION
Pulmonary Imaging: From Mouse to Man
 
Thursday 25 April 2013
Room 355 EF  10:30 - 12:30 Moderators: Grzegorz Bauman, Jens Vogel-Claussen

10:30 0642.   Molecular MR Imaging of Pulmonary Fibrosis in a Mouse Model
Peter Caravan1, Yan Yang1, Roshini Zachariah2, David E. Sosnovik1, Guangping Dai1, Bryan Fuchs2, and Michael Lanuti2
1A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States, 2Surgery, Massachusetts General Hospital, Boston, MA, United States

 
Pulmonary fibrosis is a devastating disease with poor clinical outcomes. We show that ultrashort TE imaging with a collagen-targeted gadolinium-based MR probe can specifically identify pulmonary fibrosis in a mouse model of disease.

 
10:42 0643.   
High-Resolution UTE MRI Longitudinal Non-Invasive Characterization of a Mouse Model of Chronic Asthma: From Inflammation to Bronchial Remodeling Assessment
Andrea Bianchi1, Annaig Ozier1, Olga Ousova1, Gérard Raffard2, and Yannick Crémillieux1
1Cardio-Thoracic Center of Bordeaux, University of Bordeaux Segalen, Bordeaux, France, France, 2Centre de Résonance Magnétique des Systèmes Biologiques, University of Bordeaux Segalen, Bordeaux, France, France

 
Ultra-short echo time (UTE) MRI was already shown to be appropriate for the quantification of the peribronchovascular inflammation typical of the first phase of the chosen ovalbumin model of asthma. The high quality of the images indicated the possibility of extending the protocol until the last phases of the model, in order to assess also the remodeling associated with the disease. We present here an UTE proton MRI high-resolution investigation of a chronic model of asthma in mice whose purpose is to longitudinally assess all the main hallmarks of the asthma model (including bronchial remodeling) using a fully non-invasive approach.

 
10:54 0644.   Imaging of Lung Structure and Function in the Same Breath with Triple Nuclear (He-Xe-H) MRI
Jim M. Wild1, Helen Marshall1, Xiaojun Xu1, Graham Norquay1, Steven Parnell1, Matthew Clemence2, Paul Griffiths1, and Juan Parra-Robles1
1Academic Radiology, University of Sheffield, Sheffield, Yorkshire, United Kingdom, 2Philips Medical Systems, Best, Netherlands, Netherlands

 
The purpose of this work was development of methods for the acquisition, in the same breath-hold, of lung images from two hyperpolarized gases (3He and 129Xe) with simultaneous registered anatomical 1H MR images of lung structure.

 
11:06 0645.   
Progress in MR Elastography of Human Lung Parenchyma: Evaluation of Regional Density Measurements and Faster Imaging Sequences
Yogesh K. Mariappan1, David L. Levin1, Kevin J. Glaser1, Richard Leroy Ehman1, and Kiaran P. McGee1
1Department of Radiology, Mayo Clinic, Rochester, MN, United States

 
It has been shown that pulmonary MR Elastography (MRE) can resolve the effective stiffness of human lung parenchyma using a short-TE spin echo (SE) technique. In this work, estimation of true parenchymal stiffness is described and involves the application of a SE EPI MRE sequence and GRE lung density estimation technique. This approach was evaluated on a preserved lung specimen and on healthy human volunteers. Stiffness values obtained with the EPI-MRE sequence were comparable to those from the SE technique. In addition, measured lung tissue density and true stiffness values were in agreement with previously reported estimates.

 
11:18 0646.   Lung Tissue Differentiation with Magnetization Transfer Prepared Multi-Echo Ultrashort Echo Time MRI
Kevin M. Johnson1, Scott K. Nagle1,2, Orhan Unal1,2, and Sean B. Fain1,2
1Medical Physics, UW-Madison, Madison, WI, United States, 2Radiology, UW-Madison, Madison, WI, United States

 
Ultra-short echo time (UTE) imaging holds promise for vastly improved imaging of lung structures but offers little tissue contrast. In this work we investigate the combination of UTE with several conventional echo times and magnetization transfer to separate species based on T2*. Feasibility images were collected in excised swine and human lungs. Ex-vivo images demonstrate successful separation of fluid from short T2* lung tissue and MT effect in all tissue. In human images, short T2* bone and long tissue were separated from long T2 muscle and fat.

 
11:30 0647.   
Oxygen Enhanced Lung MRI by Simultaneous Measurement of T1 and T2* During Free Breathing
Simon Triphan1,2, Felix A. Breuer1, Hans-Ulrich Kauczor2, and Peter M. Jakob1,3
1Research Centre Magnetic Resonance Bavaria e.V., Würzburg, Bayern, Germany, 2Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Baden-Württemberg, Germany, 3Experimental Physics 5, University Würzburg, Würzburg, Bayern, Germany

 
While both T1 and T2* are reduced in hyperoxic conditions, these changes reflect different aspects of lung function. A method for measuring both parameters simultaneously using a inversion recovery multi-gradient echo experiment is proposed. By applying an asymmetric radial readout with a golden angle distribution, lung signal is maximised while enabling self-gating to compensate for breathing motion. Since the dc-signal is distorted by the inversion recovery, a correction to recover an undisturbed signal is shown. Generating self-gated parameter maps provides co-registration for T1 and T2* maps as well as for maps acquired under different oxygenation conditions.

 
11:42 0648.   
Dynamic OE-MRI of the Lung in Asthma
Weijuan Zhang1,2, Robert M. Niven3,4, Simon S. Young5, Yuzhen Liu5, Penny L. Hubbard1,2, Geoffrey J. M. Parker1,2, and Josephine H. Naish1,2
1Centre of Imaging Sciences, The University of Manchester, Manchester, United Kingdom, 2Biomedical Imaging Institute, The University of Manchester, Manchester, United Kingdom, 3North West Lung Centre, University Hospital of South Manchester, Manchester, United Kingdom, 4Department of Respiratory Medicine, University Hospital of South Manchester, Manchester, United Kingdom,5Personalised Healthcare and Biomarkers, AstraZeneca, Alderley Park, United Kingdom

 
This study estimated the feasibility of dynamic OE-MRI in the assessment of lung functional changes in asthmatic patients and explored the correlation between dynamic OE-MRI and spirometry.

 
11:54 0649.   
Quantification of Ventilation and Perfusion Using Non-Contrast Enhanced Quasi-Randomly Acquired DC Gated 1H Lung Imaging
André Fischer1, Christian O. Ritter1, Stefan Weick2, Dietbert Hahn3, and Herbert Köstler1
1Institute of Radiology, University of Wuerzburg, Wuerzburg, Bavaria, Germany, 2Department of Experimental Physics 5, University of Wuerzburg, Wuerzburg, Bavaria, Germany, 3Institute of Radiology, University of Würzburg, Wuerzburg, Bavaria, Germany

 
This abstract describes the quantification of pulmonary perfusion and ventilation using non-contrast enhanced quasi-randomly acquired DC gated 1H lung imaging. By properly selecting data according to the DC gating signal which reflects signal variations induced by respiration and pulsatile blood flow, images of the respiratory and cardiac standard cycles are obtained. From these, quantification of perfusion (by a concept called AQUAPICSS) and ventilation (by comparing expiration to inspiration signal levels) is possible. Perfusion rates are in accordance with literature values and additionally performed SEEPAGE experiments. Ventilation rates were derived in normal amplitude respiration and are, therefore, lower than previous literature values obtained in maximum amplitude respiration.

 
12:06 0650.   
Quantitative Analysis of Pulmonary Inflammation After Endobronchial Allergen Challenge Using T1-Mapping MRI
Julius Renne1, Jens Hohlfeld2, Jan Hinrichs1, Christian Schönfeld1, Marcel Gutberlet1, Carla Winkler3, Cornelia Faulenbach2, Peter M. Jakob4, Norbert Krug2, Frank Wacker1, and Jens Vogel-Claussen1
1Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Lower Saxony, Germany, 2Fraunhofer Institute for Toxicology and Experimental Medicine, Hannover, Germany,3Dep. of Pneumology, Hannover Medical School, Hannover, Germany, 4Experimental Physics (Biophysics), University of Würzburg, Würzburg, Germany

 
Endobronchial allergen challenge is an established method for the evaluation of new anti-allergic drugs. Today the concentration of eosinophilic cells is the standard readout parameter for pulmonary inflammation. Therefore repeated bronchoscopies are needed, which are a substantial burden for volunteers. A new method for identification and quantification of the pulmonary inflammation after endobronchial challenge using oxygen-enhanced pulmonary MRI (T1-mapping) is presented.

 
12:18 0651.   
Non-Contrast-Enhanced Preoperative Assessment of Lung Perfusion in Patients with Non-Small-Cell Lung Cancer Using Fourier Decomposition Magnetic Resonance Imaging -permission withheld
Gregor Sommer1,2, Michael Puderbach3, Marcel Koenigkam-Santos3,4, Christopher Draenkow5, Claus-Peter Heussel3, Hans-Ulrich Kauczor6, Heinz-Peter Schlemmer2, and Grzegorz Bauman7,8
1Radiology and Nuclear Medicine, University of Basel Hospital, Basel, Switzerland, 2Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany, 3Radiology, Thoraxklinik Heidelberg, Heidelberg, Germany, 4Radiology, University Hospital of the School of Medicine of Ribeirao Preto - University of Sao Paulo, Ribeirao Preto, Brazil, 5Surgery, Thoraxklinik Heidelberg, Heidelberg, Germany, 6Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany, 7Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany,8Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI, United States

 
This study investigates non-contrast-enhanced Fourier decomposition MRI (FD MRI) as a tool for preoperative assessment of regional lung perfusion in 15 patients with NSCLC against dynamic contrast-enhanced MRI (DCE MRI). FD MRI provides high sensitivity (84%), specificity (92%) and accuracy (91%) in detecting lobar perfusion defects. Image quality of FD MRI has shown to be less than that of its reference DCE MRI. FD MRI can quantify bilateral and lobar perfusion proportions with sufficient accuracy in both upper lobes and for bilateral comparison, but is in its present form limited by pulsation artifacts in the lower parts of the lungs.