Flow Quantification

Room 203
16:00 – 18:00

Chairs: Lawrence R. Frank and Jill O. Fredrickson

16:00 565. A Novel Flow Quantitation Method Using Fourier Velocity Encoding, C-M. Tsai and D.G. Nishimura, Stanford University, Stanford, CA, USA.
16:12 566. Comparison of PC-MRI to Computational Simulations and Digital Particle Image Velocimetry (DPIV), K.L. Wedding, M.T. Draney, J.O. Fredrickson, C.A. Taylor and N.J. Pelc, Stanford University, Stanford, CA, USA.
16:24 567. Heart Motion Adapted MR Velocity Mapping of Blood Velocity Distribution Downstream of a Prosthetic Aortic Valve, S. Kozerke, J.M. Hasenkam, E.M. Pedersen and P. Boesiger, University and ETH, Zurich, Switzerland and Aarhus University Hospital, Aarhus, Denmark.
16:36 568. Effect of Breath Holding on Blood Flow Measurement using Fast Velocity Encoded Cine MR Imaging, N. Kawada, H. Sakuma, H. Kubo, T. Hirano and K. Takeda, Mie University School of Medicine and Matsusaka Central Hospital, Mie, Japan.
16:48 569. Coronary Sinus Flow Measurement by Velocity-Encoded Cine Phase Contrast MRI: Validation by Doppler Flowmeter, G.K. Lund, M.F. Wendland, A. Schimakawa, C.B. Higgins and M. Saeed, University of California, San Francisco, CA, USA and GE Medical Systems, Milwaukee, WI, USA.
17:00 570. ACE-Inhibitor-Enhanced Cine Phase-Contrast MR Measurements of Renal Artery Velocity Waveforms in Patients with Suspected Renovascular Hypertension, V.S. Lee, A.T. Ton, N.M. Rofsky, G. Johnson, G.A. Krinsky and J.C. Weinreb, New York University, New York, NY, USA.
17:12 571. Automated Model-Based Contour Detection and Flow Quantification of Blood Flow in Small Vessels with Velocity Encoded MRI, F.M.A. Box, A. Spilt, M.A. van Buchem, J.H.C. Reiber and R.J. van der Geest, Leiden University Medical Center, Leiden, The Netherlands.
17:24 572. On-Line Phase-Contrast Blood Flow Monitoring in Small Vessels, R. van der Weide, E.P.A. Vonken, C.J.G. Bakker and M.A. Viergever, University Hospital, Utrecht, The Netherlands.
17:36 573. Accurate Measurement of Arterial Input Function (AIF) Using a 3D T1 Gradient Echo Imaging Method, K.L. Li, J.J.L. Tessier, J.C. Waterton, D. Checkley, X. Zhu and A. Jackson, University of Manchester, Manchester, UK and Zeneca Pharmaceuticals, Macclesfield, UK.
17:48 574. Velocity Profile Fitting Methods in Physiological Pulsatile Flow: Implications for MR Phase Contrast Based Wall Shear Stress Estimates, S. Ringgaard, S. Oyre, H. Stødkilde-Jørgensen and E.M. Pedersen, Aarhus University Hospital, Aarhus, Denmark.

Return to ISMRM program