|   |  | New Developments in 
Parallel Imaging RF Array Coil Design 
	Room 6C         
	11:00 - 13:00                 
	Chairs: Mary McDougall and Larence L. Wald 
	
		| Time | Prog # |  |  
		| 11:00 | 415. | 
		A 32 Channel 
		Receive-Only Head Coil and Detunable Transmit Birdcage Coil for 7 Tesla 
		Brain Imaging Graham Charles Wiggins1, 
		Christopher John Wiggins1, Andreas Potthast2, 
		Vijay Alagappan1, Oliver Kraff3,  Arne Reykowski4, 
		Lawrence L. Wald11Massachusetts 
		General Hospital, Charlestown, Massachusetts, USA; 2Siemens 
		Medical Solutions, Inc, Malvern, Pennsylvania, USA; 3University 
		Hospital Essen, Essen, Germany; 4Invivo Corporation, 
		Gainesville, Florida, USA |  
		| 11:12 | 416. | 
An Adjustable 8-Channel Coil 
Array for MRI of the Human Wrist Jurek Antonin 
Massner1, Nicola De Zanche1, Klaas Paul Pruessmann1 1University and ETH 
Zurich, Zurich, Switzerland |  
		| 11:24 | 417. | 
Experimental and Numerical 
Investigations of SENSE Array Performances from High to Ultra-High Field 
Strengths Shumin Wang1, 
Patrick J. Ledden2, Jacco A. de Zwart1, Peter van Gelderen1, 
Alan Koretsky1, Jeff H. Duyn11LFMI, 
NINDS, National Institutes of Health, Bethesda, Maryland, USA; 2Nova 
Medical, Inc., Wilmington, Massachusetts, USA |  
		| 11:36 | 418. | 
36 Channel 
Peripheral Angio Matrix Coil for 3 Tesla Volker Matschl1, 
Helmut Kess1, Karsten Jahns1, Heinz Hahn1, 
Helmut Greim1, Harald Kramer2, Stefan Schoenberg2, 
Hubertus Fischer11Siemens 
Medical Solutions, Erlangen, Germany; 2University of Munich - 
Grosshadern Campus, Munich, Germany |  
		| 11:48 | 419. | 
An 8 Channel Shoulder Coil 
for High Resolusion Imaging Yoshinori Hamamura1, 
Brian Brown1, Kyle Johnson1, Jeff Hathaway1, 
Ken Meurer1, Murray Wheeler11Invivo, 
Pewaukee, Wisconsin, USA |  
		| 12:00 | 420. | 
An Optimised 16-Element Head 
Coil for 7T with Integrated Preamplifiers Yun-Jeong Yang1, 
Nicholas Castrilla1, Cliff Mills1, Verna Fitzsimmons2, 
Joseph Murphy-Boesch11USA 
Instruments, Inc., Aurora, Ohio, USA; 2Kent State University, Kent, 
Ohio, USA |  
		| 12:12 | 421. | 
High-Field Transmission Line 
Arrays for Transmit and Receive Carl J. Snyder1, 
Lance DelaBarre1, Can Akgun1, Steen Moeller1, 
Gregor Adriany1, Kamil Ugurbil1,  John Thomas Vaughan1 1University of 
Minnesota, Minneapolis, Minnesota, USA |  
		| 12:24 | 422. | 
Twenty-Four Channel 
Receive-Only Array for Brain Imaging at 7T Patrick J. 
Ledden1, Azma Mareyam1, Shumin Wang2, Peter van 
Gelderen2, Jeff H. Duyn21Nova 
Medical, Inc., Wilmington, Massachusetts, USA; 2National Institutes 
of Health, Bethesda, Maryland, USA |  
		| 12:36 | 423. | 
A 28 Channel Bi-Lateral 
Breast Array for Accelerated MR Imaging Randy O. Giaquinto1, 
Charles McKenzie2, Daniel K. Sodickson2, Aaron K. Grant2, 
Gordon E. Murtagh1,  Robert L. Furman1, 
Leo J. Swider1, Christopher J. Hardy1, Charles L. Dumoulin11GE 
Global Research, Niskayuna, New York, USA; 2Beth Israel Deaconess 
Medical Center, Boston, Massachusetts, USA |  
		| 12:48 | 424. | 
Measuring Practical Coil 
Array Performance with Respect to Ultimate Intrinsic SNR: A Tool for Array 
Design and 
Assessment Riccardo 
Lattanzi1, 2, Aaron K. Grant2, Michael A. 
Ohliger1, 2, Daniel K. Sodickson, 121Harvard-MIT, 
Cambridge, Massachusetts, USA; 2Beth Israel Deaconess Medical Center, 
Boston, Massachusetts, USA |  |