1341
Simultaneous Reconstruction of High-resolution Multi b-value DWI with Single-shot Acquisition
Fanwen Wang1, Hui Zhang1, Fei Dai1, Weibo Chen2, Chengyan Wang3, and He Wang1,3
1Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China, 2Philips Healthcare, Shanghai, China, 3Human Phenome Institute, Fudan University, Shanghai, China
This study proposed a novel method to reconstruct four-shot high-resolution DWIs from one-shot data for multiple b-values simultaneously, enabling the physiological feature transformation through different b-value.
Figure 1: The proposed model for multi-coil high-resolution DWI reconstruction. The network combines losses from four channels to back propagate. Each channel consists of a de-aliasing layer and a data consistency layer to recover from aliasing artifacts.
Figure 2: Comparison of reconstructed images for multiple b-values in healthy volunteers. The calculated ADC maps are shown leftmost. The b-values are listed on each column. SSIMs are listed at the bottom-right of each image. The rightmost four columns represent the corresponding error maps. The error was x5 amplified for better visualization. The aliasing artifacts are shown by arrows.