3475
Optimization of Compressed SENSE accelerated Brachial Plexus MRI: Quality and Efficiency
Renwang PU1, Qingwei SONG1, Ailian LIU1, Zijing ZHANG1, Nan ZHANG1, Haonan ZHANG1, Bingbing GAO1, Lihua CHEN1, and Liangjie LIN2
1the First Affiliated Hospital of Dalian Medical Universityrsity, Dalian, China, 2Philips Healthcare, BEIJING, China
3D-NerveVIEW scan with a CSAF of 4 is recommended for brachial plexus imaging with significantly reduced scan time (381s vs 821s, 54%) and comparable image quality compared to the reference scan.
a.Coronal image of brachial plexus.The area of interest(ROI) in the nerve and muscle;b-e.Mip images of brachial plexus of sense2,cs2,cs4,cs6,respectively;the scores of image quality are 4 for b-e.
a-e:Boxplot depiction of CNR,signal of nerves,image noise and image quality,respectively.